| Age | Commit message (Collapse) | Author |
|
Change-Id: I1df0685c75fc1044ba46003a69ecc7dfc53bbc2b
Reviewed-on: https://go-review.googlesource.com/c/go/+/574675
Reviewed-by: Ian Lance Taylor <iant@google.com>
Reviewed-by: Than McIntosh <thanm@google.com>
LUCI-TryBot-Result: Go LUCI <golang-scoped@luci-project-accounts.iam.gserviceaccount.com>
Auto-Submit: Ian Lance Taylor <iant@google.com>
|
|
aix supports iovec read/write, see
https://www.ibm.com/docs/en/aix/7.2?topic=w-write-writex-write64x-writev-writevx-ewrite-ewritev-pwrite-pwritev-subroutine
Define an unexported writev wrapper in package syscall (like on openbsd
and darwin) and linkname it from internal/poll.
Change-Id: I8f9695ceac72ae861afa3692207c154d86d4e690
Reviewed-on: https://go-review.googlesource.com/c/go/+/435260
Run-TryBot: Tobias Klauser <tobias.klauser@gmail.com>
Reviewed-by: Carlos Amedee <carlos@golang.org>
Reviewed-by: Ian Lance Taylor <iant@google.com>
TryBot-Result: Gopher Robot <gobot@golang.org>
Auto-Submit: Tobias Klauser <tobias.klauser@gmail.com>
|
|
The writev syscall is available since at least Solaris 11.3.
Reuse the existing illumos writev wrapper on solaris to implement
internal/poll.writev for net.(*netFD).writeBuffers.
Change-Id: I23adc3bb4637740c72bfb61bfa9697b432dfe3db
Reviewed-on: https://go-review.googlesource.com/c/go/+/427714
Run-TryBot: Tobias Klauser <tobias.klauser@gmail.com>
TryBot-Result: Gopher Robot <gobot@golang.org>
Reviewed-by: Ian Lance Taylor <iant@google.com>
Reviewed-by: Michael Knyszek <mknyszek@google.com>
|
|
When these packages are released as part of Go 1.18,
Go 1.16 will no longer be supported, so we can remove
the +build tags in these files.
Ran go fix -fix=buildtag std cmd and then reverted the bootstrapDirs
as defined in src/cmd/dist/buildtool.go, which need to continue
to build with Go 1.4 for now.
Also reverted src/vendor and src/cmd/vendor, which will need
to be updated in their own repos first.
Manual changes in runtime/pprof/mprof_test.go to adjust line numbers.
For #41184.
Change-Id: Ic0f93f7091295b6abc76ed5cd6e6746e1280861e
Reviewed-on: https://go-review.googlesource.com/c/go/+/344955
Trust: Russ Cox <rsc@golang.org>
Run-TryBot: Russ Cox <rsc@golang.org>
TryBot-Result: Go Bot <gobot@golang.org>
Reviewed-by: Bryan C. Mills <bcmills@google.com>
|
|
Make all our package sources use Go 1.17 gofmt format
(adding //go:build lines).
Part of //go:build change (#41184).
See https://golang.org/design/draft-gobuild
Change-Id: Ia0534360e4957e58cd9a18429c39d0e32a6addb4
Reviewed-on: https://go-review.googlesource.com/c/go/+/294430
Trust: Russ Cox <rsc@golang.org>
Run-TryBot: Russ Cox <rsc@golang.org>
TryBot-Result: Go Bot <gobot@golang.org>
Reviewed-by: Jason A. Donenfeld <Jason@zx2c4.com>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
|
|
Illumos supports iovec read/write. Add the writev wrapper to
internal/syscall/unix and use it to implement internal/poll.writev for
net.(*netFD).writeBuffers.
Change-Id: Ie256c2f96aba8e61fb21991788789a049425f792
Reviewed-on: https://go-review.googlesource.com/c/go/+/254638
Run-TryBot: Tobias Klauser <tobias.klauser@gmail.com>
TryBot-Result: Go Bot <gobot@golang.org>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Trust: Tobias Klauser <tobias.klauser@gmail.com>
|
|
Historically we've assumed that we can install all signal handlers
with the SA_RESTART flag set, and let the system restart slow functions
if a signal is received. Therefore, we don't have to worry about EINTR.
This is only partially true, and we've added EINTR checks already for
connect, and open/read on Darwin, and sendfile on Solaris.
Other cases have turned up in #36644, #38033, and #38836.
Also, #20400 points out that when Go code is included in a C program,
the C program may install its own signal handlers without SA_RESTART.
In that case, Go code will see EINTR no matter what it does.
So, go ahead and check for EINTR. We don't check in the syscall package;
people using syscalls directly may want to check for EINTR themselves.
But we do check for EINTR in the higher level APIs in os and net,
and retry the system call if we see it.
This change looks safe, but of course we may be missing some cases
where we need to check for EINTR. As such cases turn up, we can add
tests to runtime/testdata/testprogcgo/eintr.go, and fix the code.
If there are any such cases, their handling after this change will be
no worse than it is today.
For #22838
Fixes #20400
Fixes #36644
Fixes #38033
Fixes #38836
Change-Id: I7e46ca8cafed0429c7a2386cc9edc9d9d47a6896
Reviewed-on: https://go-review.googlesource.com/c/go/+/232862
Run-TryBot: Ian Lance Taylor <iant@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Bryan C. Mills <bcmills@google.com>
|
|
The chunks that were referenced by fd.iovecs would not be GC.
Change-Id: I7bfcb91a3fef57a4a1861168e9cd3ab55ce1334e
GitHub-Last-Rev: e0b7f68447441fd89ed1a6e8aa37e2084fd863b2
GitHub-Pull-Request: golang/go#32138
Reviewed-on: https://go-review.googlesource.com/c/go/+/178037
Run-TryBot: Ian Lance Taylor <iant@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
|
|
Writev was allocating a new []syscall.Iovec every call, rather than
reusing the cached copy available at *fd.iovec.
Fixes #26663.
Change-Id: I5967b0d82dc671ce0eaf4ec36cc2a0e46eadde02
Reviewed-on: https://go-review.googlesource.com/c/go/+/172419
Run-TryBot: Matthew Dempsky <mdempsky@google.com>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
|
|
There are still some references to the bare Syscall functions
in the stdlib. I will root those out in a following CL.
(This CL is big enough as it is.)
Most are in vendor directories:
cmd/vendor/golang.org/x/sys/unix/
vendor/golang_org/x/net/route/syscall.go
syscall/bpf_bsd.go
syscall/exec_unix.go
syscall/flock.go
Update #17490
Change-Id: I69ab707811530c26b652b291cadee92f5bf5c1a4
Reviewed-on: https://go-review.googlesource.com/c/141639
Run-TryBot: Keith Randall <khr@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Elias Naur <elias.naur@gmail.com>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
|
|
In the past we returned "use of closed network connection" when using
a closed network descriptor in some way. In CL 36799 that was changed
to return "use of closed file or network connection". Because programs
have no access to a value of this error type (see issue #4373) they
resort to doing direct string comparisons (see issue #19252). This CL
restores the old error string so that we don't break programs
unnecessarily with the 1.9 release.
This adds a test to the net package for the expected string.
For symmetry check that the os package returns the expected error,
which for os already exists as os.ErrClosed.
Updates #4373.
Fixed #19252.
Change-Id: I5b83fd12cfa03501a077cad9336499b819f4a38b
Reviewed-on: https://go-review.googlesource.com/39997
Run-TryBot: Ian Lance Taylor <iant@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
Reviewed-by: Russ Cox <rsc@golang.org>
|
|
Change-Id: I283f4453e5cf8b22995b3abffccae182cfbb6945
Reviewed-on: https://go-review.googlesource.com/36970
Reviewed-by: Dave Cheney <dave@cheney.net>
Reviewed-by: Ian Lance Taylor <iant@golang.org>
Run-TryBot: Dave Cheney <dave@cheney.net>
TryBot-Result: Gobot Gobot <gobot@golang.org>
|
|
This will make it possible to use the poller with the os package.
This is a lot of code movement but the behavior is intended to be
unchanged.
Update #6817.
Update #7903.
Update #15021.
Update #18507.
Change-Id: I1413685928017c32df5654ded73a2643820977ae
Reviewed-on: https://go-review.googlesource.com/36799
Run-TryBot: Ian Lance Taylor <iant@golang.org>
TryBot-Result: Gobot Gobot <gobot@golang.org>
Reviewed-by: David Crawshaw <crawshaw@golang.org>
Reviewed-by: Russ Cox <rsc@golang.org>
|