aboutsummaryrefslogtreecommitdiff
path: root/src/cmd/internal/obj/mips/obj0.go
AgeCommit message (Collapse)Author
2016-10-28cmd/internal/obj/mips: materialize float constant 0 from zero registerCherry Zhang
Materialize float constant 0 from integer zero register, instead of loading from constant pool. Change-Id: Ie4728895b9d617bec2a29d15729c0efaa10eedbb Reviewed-on: https://go-review.googlesource.com/32109 Run-TryBot: Cherry Zhang <cherryyz@google.com> TryBot-Result: Gobot Gobot <gobot@golang.org> Reviewed-by: David Chase <drchase@google.com>
2016-10-25cmd/internal/obj: Use bitfield for LSym attributesshaharko
Reduces the size of LSym struct. On 32bit: before 84 after 76 On 64bit: before 136 after 128 name old time/op new time/op delta Template 182ms ± 3% 182ms ± 3% ~ (p=0.607 n=19+20) Unicode 93.5ms ± 4% 94.2ms ± 3% ~ (p=0.141 n=20+19) GoTypes 608ms ± 1% 605ms ± 2% ~ (p=0.056 n=20+20) name old user-ns/op new user-ns/op delta Template 249M ± 7% 249M ± 4% ~ (p=0.605 n=18+19) Unicode 149M ±14% 151M ± 5% ~ (p=0.724 n=20+17) GoTypes 855M ± 4% 853M ± 3% ~ (p=0.537 n=19+19) name old alloc/op new alloc/op delta Template 40.3MB ± 0% 40.3MB ± 0% -0.11% (p=0.000 n=19+20) Unicode 33.8MB ± 0% 33.8MB ± 0% -0.08% (p=0.000 n=20+20) GoTypes 119MB ± 0% 119MB ± 0% -0.10% (p=0.000 n=19+20) name old allocs/op new allocs/op delta Template 383k ± 0% 383k ± 0% ~ (p=0.703 n=20+20) Unicode 317k ± 0% 317k ± 0% ~ (p=0.982 n=19+18) GoTypes 1.14M ± 0% 1.14M ± 0% ~ (p=0.086 n=20+20) Change-Id: Id6ba0db3ecc4503a4e9af3ed0d5884d4366e8bf9 Reviewed-on: https://go-review.googlesource.com/31870 Reviewed-by: David Crawshaw <crawshaw@golang.org> Run-TryBot: Shahar Kohanim <skohanim@gmail.com> TryBot-Result: Gobot Gobot <gobot@golang.org>
2016-10-24cmd/internal/obj/mips: store LR before update SP in function prologueCherry Zhang
This prevents the traceback code from seeing a half-updated stack frame when a profiling signal comes during the execution of function prologue. Also fixes mips64x part of #17381. Change-Id: Iec9683427e546e3648b2e8b1dde956d13f6eb938 Reviewed-on: https://go-review.googlesource.com/31721 Run-TryBot: Cherry Zhang <cherryyz@google.com> TryBot-Result: Gobot Gobot <gobot@golang.org> Reviewed-by: Austin Clements <austin@google.com>
2016-08-25cmd/compile: get MIPS64 SSA workingCherry Zhang
- implement *, /, %, shifts, Zero, Move. - fix mistakes in comparison. - fix floating point rounding. - handle RetJmp in assembler (which was not handled, as a consequence Duff's device was disabled in the old backend.) all.bash now passes with SSA on. Updates #16359. Change-Id: Ia14eed0ed1176b5d800592080c8f53dded7fe73f Reviewed-on: https://go-review.googlesource.com/27592 Reviewed-by: David Chase <drchase@google.com> Run-TryBot: Cherry Zhang <cherryyz@google.com> TryBot-Result: Gobot Gobot <gobot@golang.org>
2016-08-25cmd/link/internal, cmd/internal/obj: introduce ctxt.LogfDave Cheney
Replace the various calls to Fprintf(ctxt.Bso, ...) with a helper, ctxt.Logf. This also addresses the various inconsistent flushing of ctxt.Bso. Because we have two Link structures, add Link.Logf in both places. Change-Id: I23093f9b9b3bf33089a0ffd7f815f92dcd1a1fa1 Reviewed-on: https://go-review.googlesource.com/27730 Reviewed-by: Matthew Dempsky <mdempsky@google.com>
2016-08-25cmd/internal/*: only call ctx.Bso.Flush when something has been writtenDave Cheney
In many places where ctx.Bso.Flush is used as the target for some debug logging, ctx.Bso.Flush is called unconditionally. In the majority of cases where debug logging is not enabled, this means Flush is called many times when there is nothing to be flushed (it will be called anyway when ctx.Bso is eventually closed), sometimes in a loop. Avoid this by moving the ctx.Bso.Flush call into the same condition block as the debug print. This pattern was previously applied sporadically. Change-Id: I0444cb235cc8b9bac51a59b2e44e59872db2be06 Reviewed-on: https://go-review.googlesource.com/27579 Run-TryBot: Dave Cheney <dave@cheney.net> TryBot-Result: Gobot Gobot <gobot@golang.org> Reviewed-by: David Crawshaw <crawshaw@golang.org> Reviewed-by: Matthew Dempsky <mdempsky@google.com>
2016-05-02all: make copyright headers consistent with one space after periodEmmanuel Odeke
Follows suit with https://go-review.googlesource.com/#/c/20111. Generated by running $ grep -R 'Go Authors. All' * | cut -d":" -f1 | while read F;do perl -pi -e 's/Go Authors. All/Go Authors. All/g' $F;done The code in cmd/internal/unvendor wasn't changed. Fixes #15213 Change-Id: I4f235cee0a62ec435f9e8540a1ec08ae03b1a75f Reviewed-on: https://go-review.googlesource.com/21819 Reviewed-by: Ian Lance Taylor <iant@golang.org> Run-TryBot: Ian Lance Taylor <iant@golang.org> TryBot-Result: Gobot Gobot <gobot@golang.org>
2016-04-07cmd: add new common architecture representationMatthew Dempsky
Information about CPU architectures (e.g., name, family, byte ordering, pointer and register size) is currently redundantly scattered around the source tree. Instead consolidate the basic information into a single new package cmd/internal/sys. Also, introduce new sys.I386, sys.AMD64, etc. names for the constants '8', '6', etc. and replace most uses of the latter. The notable exceptions are a couple of error messages that still refer to the old char-based toolchain names and function reltype in cmd/link. Passes toolstash/buildall. Change-Id: I8a6f0cbd49577ec1672a98addebc45f767e36461 Reviewed-on: https://go-review.googlesource.com/21623 Reviewed-by: Michael Hudson-Doyle <michael.hudson@canonical.com> Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org> Run-TryBot: Matthew Dempsky <mdempsky@google.com> TryBot-Result: Gobot Gobot <gobot@golang.org>
2016-04-03all: fix spelling mistakesEric Engestrom
Signed-off-by: Eric Engestrom <eric@engestrom.ch> Change-Id: I91873aaebf79bdf1c00d38aacc1a1fb8d79656a7 Reviewed-on: https://go-review.googlesource.com/21433 Reviewed-by: Ian Lance Taylor <iant@golang.org> Run-TryBot: Ian Lance Taylor <iant@golang.org> TryBot-Result: Gobot Gobot <gobot@golang.org>
2016-03-28cmd/internal/obj: convert fields of LSym from uint8 to boolMarvin Stenger
No performance regression measurable: name old time/op new time/op delta Template 432ms ± 3% 422ms ± 2% -2.34% (p=0.010 n=10+9) GoTypes 1.46s ± 1% 1.46s ± 1% ~ (p=0.796 n=10+10) Compiler 7.15s ± 1% 7.14s ± 1% ~ (p=0.447 n=10+9) Change-Id: I21b93cb989017b6fec2215de2423d87f25cf538c Reviewed-on: https://go-review.googlesource.com/21220 Reviewed-by: David Crawshaw <crawshaw@golang.org> Run-TryBot: David Crawshaw <crawshaw@golang.org> TryBot-Result: Gobot Gobot <gobot@golang.org>
2016-03-08cmd/internal/obj: add As type for assembly opcodesMatthew Dempsky
Passes toolstash/buildall. Fixes #14692. Change-Id: I4352678d8251309f2b8b7793674c550fac948006 Reviewed-on: https://go-review.googlesource.com/20350 Reviewed-by: Dave Cheney <dave@cheney.net> Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org>
2016-02-24all: fix typos and spellingMartin Möhrmann
Change-Id: Icd06d99c42b8299fd931c7da821e1f418684d913 Reviewed-on: https://go-review.googlesource.com/19829 Reviewed-by: Brad Fitzpatrick <bradfitz@golang.org> Run-TryBot: Brad Fitzpatrick <bradfitz@golang.org> TryBot-Result: Gobot Gobot <gobot@golang.org>
2015-11-12cmd/internal/obj/mips: added support for GOARCH=mips64{,le}Yao Zhang
MIPS64 has 32 general purpose 64-bit integer registers (R0-R31), 32 64-bit floating point registers (F0-F31). Instructions are fixed-width, and are 32-bit wide. Instructions are all in standard 1-, 2-, 3-operand forms. MIPS64-specific relocations are added. For this reason, test data of cmd/newlink are regenerated. No other changes are made to portable structures. Branch delay slots are current filled with NOP instructions. The function for instruction scheduling (try to fill the delay slot with a useful instruction) is implemented but disabled for now. Change-Id: Ic364999c7a33245260c1381fc26a2fa8972d38b3 Reviewed-on: https://go-review.googlesource.com/14442 Reviewed-by: Minux Ma <minux@golang.org>
2015-09-08cmd/internal/obj/mips: copy cmd/internal/obj/ppc64Shenghou Ma
Just a mechanical copy with filename renames, no code changes. This is to reduce code difference when adding the mips64 port. Change-Id: Id06e975f414a7b09f4827167b30813b228a3bfae Reviewed-on: https://go-review.googlesource.com/14323 Reviewed-by: Ian Lance Taylor <iant@golang.org>